Activation
The Voice call will be sent when an event assigned to a telephone number
programmed with a Voice message occurs. Below is the step by step
Voice call procedure (see also figure 42).
1. The Control panel will engage the connected telephone line.
2. The Control panel will wait 10 seconds for the Dial Tone.
----If the dial tone is detected, the Control panel will go to step 3.
----If the dial tone is not detected the Control panel will hang up and step
back to step 1.
+
If the switchboard operates with non-standard tones, it may be necessary
to disable the Tone Check. In this way the Control panel will skip step 2.
and go directly to step 3.
3. The Control panel will dial the programmed telephone number.
4. The Control panel will wait for the Line Free tone.
----If the Line Free tone is detected the Control panel will go to step 5.
----If the Line Busy tone is detected the Control panel will hang up and
step back to step 1.
5. The Control panel will wait for an answer.
----If the call is answered the Control panel will step to step 6
----If the call is unanswered the Control panel will hang up and step back to
step 1.
6. The Control panel will play the message(s) recorded on the NormaVOX2
board.
The COntrol panel will retry for a further 8 times before quitting unan-
swered calls.
Figure 42 Voice Call Flow chart