Connection of control panel to PC and Modem to PC
Control panel
PC connection
The programmed parameters must be downloaded onto the memory of the
corresponding control panel. Therefore, it is necessary to make a serial
connection between the PC and the connector 7 of the control panel.
Use a CVSER/9F9F serial cable (not supplied), or make the cable as per
the following diagram.
If the PC serial ports have 25 pole connectors, use an ADSER/9M25F
adapter (not supplied), or make the cable as per the following diagram.
The Main unit must be open during programming, therefore, only author-
ized personnel can access the programming phase. The User must enable
the Teleservice option, otherwise, the control panel will be unable to an-
swer incoming Teleservice calls (refer to "Enable/Disable Teleservice"
paragraph in the USER MANUAL).
+
Specify the PC serial port used for the connection with the Control panel in
the Serial port settings window (refer to "Serial Ports" paragraph).
Figure 40
PROGRAMMING FROM PC 75