Typical installation
A diagram of a typical installation of the Omnia8 Control panel can be found in
the previous pages.
From left to right:
Ø Connection of the telephone line
Ø Connection of signalling devices ----indoor siren and self-powered siren
Ø Connection of three burglar sensors to line L1
Ø Connection of three fire sensors to line L8
Ø Connection of the Tamper line
Ø Connection of one Keypad and one Key reader to the BPI bus
Please note:
Ø Line L1 must be programmed as Balanced 10K as there is a 10 K balance
resistor.
Ø Line L8 must be programmed as Fire, and the auxiliary output (terminal
24[O2]) as Fire GND and Normally Closed.
The connections of the other Alarm lines are not shown, as burglar sen-
sors are connected as per line L1, and fire sensors are connected as per
line L8.
+
Use shielded cable with one end the connected to the Main Unit ground
and the other connected to the device ground.
34 Security System Control Panels Omnia8/Omnia4