If no key number is entered, and is pressed, the digital key number will
correspond to the current number stored in the control panel memory.
To program the digital key features:
KEYS Setting options Data
digital key valid on partition 1
digital key valid on partition 2
digital key valid on partition 3
digital key valid on partition 4
valid service digital key (for service mode)
valid digital key (non-service)
Ø Insert the digital key into the selected key reader and wait for the beep.
During this phase it will be possible to program all the digital keys, and also
change the setting options displayed on the keypad.
All digital keys programmed after 128 will be clones, that is, with identical
features as digital key 128.
Press to quit.
To read a new Random code on a digital key Address 421:
1. Enter 421.
2.
Press .
3. Select key reader: 1 through 16.
4.
Press .
5. Insert the digital key to read the random code. A long high-tone beep will
confirm Operation Done.
Add. Description
419 generates new Random code u
420 select key reader v select key no. v set options and insert key
421 select key reader v insert key to read new random code
422 select key no.v set options u (Prog.)
Electronic keys
for MASTER /
SLAVE systems
A MASTER / SLAVE system must have 2 or more control panels. MASTER /
SLAVE systems are configured as follows: 1) one MASTER control panel; 2)
one (or more) SLAVE control panel(s). Electronic keys must be programmed
on the MASTER control panel, and can be used on all the control panels of
a MASTER / SLAVE system.
To configure a control panel as MASTER: carry out Address 419 procedure.
110 Security System Control panels Omnia8/Omnia4