Command zones Command zones can be programmed as either "Arm partitions" or
"Switch partitions" zones.
Violation or tamper of a Command zone programmed as "Arm partitions"
will arm the partitions the zone is assigned to.
Violation or tamper of a Command zone programmed as "Switch parti-
tions" will switch the status of the partitions the zone is assigned to.
+
Violation or tamper of a Command zone will not generate alarm or tamper
status, it will not be signalled on the keypads, stored in the alarm memory
or logged in the Event Buffer. Command zones cannot be bypassed.
Zone table
The Zone table on the left-hand side of the programming page shows the
available zones. The Data entered on the right-hand side of the page will
be transferred automatically to the table. Select the zone number (1
through 8).
no. This is the zone Identifier number that, where necessary, will be used in-
stead of the full description (refer to "Description").
Ter. This is the abbreviation used for zone terminal.
Description This is the zone label (16 characters maximum), and will be used in all
parts of the program as the zone Identifier.
Partitions These are the partitions of the zone.
Types
Select the required zone type from the 6 options in the "Types" section.
Instant An instant alarm will be generated if this type of alarm zone is violated dur-
ing armed-unbypassed status.
Delayed Violation of an armed Delayed zone will trigger the alarm delay. If the con-
trol panel is not disarmed before the delay expires, the control panel will
generate an alarm event.
+
Violation of this type of alarm zone during the Exit Time delay will not gen-
erate an alarm.
Path This is the path from a Delayed zone to a disarm-point. The Entry Time
Delay will start when the Delayed zone (entrance) is violated. The Entry
Time Delay will give the user time to reach the disarm-point and disarm
the partition. An instant alarm will be generated, if this zone is violated be-
fore a Delayed zone. During the Exit Time delay this zone type will oper-
ate in the same way as a delayed zone.
24h An instant alarm will be generated, if this zone is violated (when unby-
passed), whatever the status (armed/disarmed) of the partitions it is as-
signed to.
PROGRAMMING 41