Power supply connection
The Control panel is powered by the Mains (230 V/50 Hz) through an on-
board power supply.
The battery (13.8 V, 7 Ah max. not supplied) will supply the power during
mains failure. Mains failure will be signalled as follows:
Ø The TROUBLE LED on the Control Keypad will go ON.
Ø Activation of one of the auxiliary outputs: 23[O1], 24[O2] ----if programmed
for "TROUBLE" signalling.
The cause of trouble must always be found and eliminated before the bat-
tery empties. Total power failure (mains and battery) will not affect the con-
figuration, as the non-volatile memory will save any changes made during
Armed status.
To connect power supply:
1. Disable the tamper microswitch 8 (if installed).
2.
Connect the Earth to terminal [ ] on the terminal board 11.
3. Connect Neutral to terminal [N] and Line to terminal [L] on the terminal
board 11.
4. Connect the battery to the battery connectors 14.
5. Disable the Alarm Output, as per the instructions in the "Open Main Unit"
paragraph.
+
Once the Main Unit is installed ----release the tamper microswitch 8 (if in-
stalled), and close the panel.
BPI bus
Configuration
On initial Startup the Control panel will assign address 1 to the Keypad (re-
fer to "Device Address"). This will be the basic configuration of the system.
The installer must put all the other devices in the configuration. Devices
that are not in the configuration will not be controlled by the Control panel.
30 Security System Control Panels Omnia8/Omnia4