Telephone
This page holds the 8 telephone numbers that Control panel manages, and
the telephone line data.
Dialling
Disable Tone
check
If the Disable Tone Check is selected the control panel will dial the tele-
phone numbers without checking for the dial tone. This option is useful
when the Control panel is connected downstream to a switchboard with
non-standard tones.
If the Disable Tone Check is not selected the Control panel will check for
the dial tone before dialling and, if the dial tone is not present, will hang-up
and retry.
Pulse Dialling If Pulse dialling is selected the Control panel will dial in Pulse mode.
If Pulse dialling is not selected the Control panel will dial in DTMF mode.
If both modes are available select DTMF as it is faster.
no. This is the identifier number of the telephone number (1 through 8) used
in place of the full number in many parts of the program.
Number The telephone numbers in this list can be dialled by the Digital communica-
tor, the Telephone Dialler, and can also be used for Teleservice. Each tele-
phone number can have a maximum of 16 digits (0 through 9). The comma
(,) is for pauses (for example, between a telephone number and area
code).
Description The telephone number description (maximum 16 characters) will identify
the user.
Types
Use this section to define the telephone number type: Telemonitoring,
Teleservice, Voice Message (this feature requires the NormaVOX2
board).
Telemonitoring
Telemonitoring telephone numbers require the following specifications.
Communication
Protocol
The Central station can assign one of the following data transfer protocols:
Ø ADEMCO / SILENT KNIGHT - slow 10 baud - 3/1, 4/1, 4/2
Ø ADEMCO / SILENT KNIGHT - fast i4 baud - 3/1, 4/1, 4/2
Ø FRANKLIN / SESCOA / DCI / VERTEX - Fast 20 baud - 3/1, 4/1, 4/2
Ø RADIONICS - 40 baud - 3/1, 4/1, 4/2
Ø SCANTRONIC - 10 baud - 3/1, 4/1, 4/2
Ø CONTACT ID
54 Security System Control Panels Omnia8/4