Entry time The output will be activated during the Entry time of the partitions it is as-
signed to.
Chime The output will be activated when a Chime zone is violated during dis-
armed status, of one or more of the partitions the zone is assigned to.
+
The output must be assigned to one or more of the partitions of the zone.
Arming delay This output will be activated during the Arming delay of the partitions it is
assigned to.
Alarm and
Tamper
The output will be activated in the event of alarm or tamper on one or more
zones of a partition the output is assigned to.
+
The AIarm and Tamper signal does not signal system tamper (Terminal
[AS] unbalanced, False key, Keypad tamper).
Fire GND The Reset Alarm Memory command will activate the output for 10 sec-
onds. The keypad and Code PIN in use must be enabled on one or more
of the partitions the output is assigned to.
It is possible to use an output as the negative power supply to the fire sensors.
In this case, the output must be programmed with the Normally Closed attrib-
ute and the Fire GND signal. The Reset Alarm Memory command will cause
the negative to fail for 10 seconds, and will reset the fire sensors.
Telephone line
trouble
The output will be activated for 15 minutes when the telephone line current
drops below 3 V for more than 30 seconds. The output will return to
standby status 15 minutes after restoral.
Figure 25 Outputs page
PROGRAMMING 45