EVENT OCCURS when ...
01
:
04
Alarm
Partition no.
... one of the zones assigned to the Partition is in alarm status
1
05
:
12
Alarm Zone
no.
... the Zone is in alarm status
1
N.B. Only Events no. 5 (Alarm Zone no. 1), 6 (Alarm Zone no. 2),
7 (Alarm Zone no. 3) and 8 (Alarm Zone no. 4) are valid for Omnia4.
13 Tamper
.... one of the following conditions occurs:
Zone tamper (Balanced, Double Balanced); Terminal [AS] unbalanced,
False key
2
; Keypad Tamper
3
.
14
Mains Trouble
.... mains power fails for over the programmed time allowed (refer to the
"Options" paragraph in the "Programming" chapter)
15
Low Battery
Trouble
... the battery is low or empty, and therefore, unable to power the control
panel. The battery is constantly monitored by the system (dynamic
check), however, in the event of black-out a static check will be done.
16 Fuse Trouble ... fuse 5 blown
17 BPI Trouble ... one or more BPI devices fails to respond
18
:
25
Reset Alarm
Zone no.
... standby status restored on the zone, and all alarm generating
conditions no longer present
N.B. Only Events no. 18 (Reset Alarm Zone no. 1), 19 (Reset Alarm
Zone no. 2), 20 (Reset Alarm Zone no. 3) and 21 (Reset Alarm Zone no.
4) are valid for Omnia4.
26 Reset
Tamper
... alarm status ends, and all conditions that generate the tamper event
(Zone tamper; Terminal [AS] unbalanced; False key
2
; Keypad Tamper
3
)
are no longer present
27 Reset Mains
Trouble
... mains power restored
28
Reset Low
Battery
Trouble
... battery recharged
29
Reset Fuse
Trouble
... fuse 5 replaced
30
Reset BPI
Trouble
... all BPI bus devices in the configuration respond
31 Superkey 1 ... key 1 pressed for 4 seconds
32 Superkey 2 ... key 2 pressed for 4 seconds
33 Superkey 3 ... key 3 pressed for 4 seconds
34
:
37
Partition no.
Armed
... partition armed by a Code or digital key
38
:
41
Partition no.
Disarmed
... partition disarmed by a Code or digital key
42
:
45
Special
Arming
Partition no.
... partition armed by: Command zone; Timer; PC (via modem)